Manufacturer | Traffic Group Signals Ltd |
---|---|
Specification Number | TOPAS 2503B |
Specification Status | Superseded |
Product Ref | PDL 2030 |
Registration Date | 14/08/2015 |
Certificate Number | 2020/0165 |
Additional Documentation | Download |
Product Details:
TOPAS Re-Registration 3/7/20 Certificate 2020/0165
Exceptions : In respect of TOPAS 2502B, TOPAS 2503B, TOPAS 2538B and TOPAS 2537A
SA/SD Equipment: (TOPAS 2537A clause 2.58 & TOPAS 2338A clause 2.57) This function is not included with this eqiupment.
Cat 1 Failure mode: (TOPAS 2502B clause 2.60, TOPAS 2537A clause 2.71 and TOPAS 2538A clause 2.70): Note : rather than transition immediately to all red, the system enters a HOLD state in which no signalling transitions can occur. This lasts for up to 12 seconds, during which time the system works to find a viable alternative radio channel on which to resume operation, in the event that this operation is unsuccessful, the system transitions to immediate lights out state
Vehicle to Pedestrian Intergreen: (TOPAS 2537A clause 2.4): Controllers will run preceding vehicle all red time, prior to pedestrian green. A minimum of 3 second all red period will be achieved.
Pedestrian Green Time: (TOPAS 2537A clause 2.42 and TOPAS 2538A clause 2.39): The controllers offer alternative pedestrian green times, always with a minimum of 7 seconds.
Automatic Comms Recovery: (TOPAS 2502B clause 2.61; TOPAS 2503B clause 2.60; TOPAS 2537A clauses 2.72 and TOPAS 2538A clause 2.71): Following a CAT1 fault, the system waits for a variable hold-off period before then automatically attempting to restart the system through the safe start-up sequence. The hold off period starts at 5 seconds then increases to 1 minute, then 2, 5, 15,30 in the event that subsequent attempts to restart are not successful.
Minimum Green Time : (TOPAS 2502B clause 2.28; TOPAS 2503B clause 2.31; TOPAS 2537A clause 2.31; TOPAS 2538A clause 2.29) The minimum green time employed when operating in Vehicle Actuation mode is 12 seconds but is automatically reduced to a value between 6 and 12 seconds in cases where the maximum green time is set by the operative to a value of 15 seconds or less.
Red Times (TOPAS 2537A clause 2.32) All-red times are selectable in one second increments
Maximum Green Times : (TOPAS 2502B clause 2.34; TOPAS 2503B caluse 2.33; TOPAS 2537A clause 2.39; TOPAS 2538A clause 2.36) Maximum green times are selectable between 6 seconds and 60 seconds in 1 second increments. A ‘hidden’ function is available to advanced users (under highway authority instruction) in order to allow maximum green times in the range of 6 – 15 seconds to be set.
CAT 3 fault : (TOPAS 2502B clause 2.62; TOPAS 2537A clause 2.73: TOPAS 2538A clause 2.72) When a CAT 3 fault occurs, all signal heads in the system automatically complete any amber transition currently in progress
——
TOPAS Registration 14/8/15 Certificate Number 2015/0093
HA Approval 31/3/15 TR2503B